Home   |   Technical Articles

Technical Articles

What is the difference between IEC 61000-4-2 and HBM?

In the world of electrical engineering, there are various standards and specifications that define the requirements for testing and evaluating the susceptibility of electronic devices to electromagnetic disturbances. Among these, IEC 61000-4-2 and Human Body Model (HBM) are two commonly used methods. While they share the same purpose, there are notable differences between the two. This article will shed light on their dissimilarities, offering a comprehensive understanding of IEC 61000-4-2 and HBM.

IEC 61000-4-2

IEC 61000-4-2 is an international standard published by the International Electrotechnical Commission (IEC) that specifically addresses electrostatic discharge (ESD) immunity testing. ESD occurs when there is a flow of electricity between two electrically charged objects due to contact or an electrical short. The purpose of IEC 61000-4-2 is to assess the performance of electronic equipment under realistic ESD conditions.

HBM: Understanding the Human Body Model

The Human Body Model (HBM) is a method designed to simulate an electrostatic discharge event that occurs when a human touches an electronic device and subsequently discharges the accumulated static charge. In this model, the human body acts as a capacitor, storing an electrostatic charge which can be transferred to sensitive electronic components upon contact. The HBM test evaluates a device's immunity to such electrostatic discharges.

Differences Between IEC 61000-4-2 and HBM

While both IEC 61000-4-2 and HBM serve the purpose of assessing electrostatic discharge susceptibility, there are several key differences between the two methods:

Test Levels: IEC 61000-4-2 defines specific test levels for ESD immunity, ranging from 2 kV to 15 kV. HBM, on the other hand, typically uses higher test levels, usually in the range of 8 kV to 16 kV.

Waveform: IEC 61000-4-2 utilizes a waveform called the "150 pF/330 Ω" combination network to simulate the discharge, while HBM employs a waveform that represents the human body's discharge characteristics.

Test Setup: The setup for IEC 61000-4-2 involves using a discharge pistol or a contact discharge finger, whereas HBM testing requires a specially designed discharge station that closely resembles a human finger.

Application: While IEC 61000-4-2 is widely used for testing electronic devices across various industries, HBM is primarily used in the semiconductor and integrated circuit (IC) manufacturing sector.

In conclusion, both IEC 61000-4-2 and HBM are essential methods for evaluating the susceptibility of electronic devices to electrostatic discharges. While IEC 61000-4-2 encompasses a broader range of applications and uses lower test levels, HBM focuses specifically on simulating the discharge caused by human contact and employs higher test levels. Understanding the differences between these techniques allows engineers to choose the most appropriate method for assessing the ESD immunity of their devices.

Contact Us

Contact: Nina She

Phone: +86-13751010017

Tel: +86-755-33168386

Add: 1F Junfeng Building, Gongle, Xixiang, Baoan District, Shenzhen, Guangdong, China

close
Scan the qr codeClose
the qr code