Home   |   Technical Articles

Technical Articles

What is ISO 10993192017

In this in-depth technical article, we delve into the details of ISO 10993-1:2017 and explore its significance in the field of medical device testing and evaluation.

The Importance of ISO 10993-1:2017

ISO 10993-1 is an international standard developed by the International Organization for Standardization (ISO) that addresses the biological evaluation of medical devices. This standard plays a crucial role in ensuring the safety and effectiveness of medical devices before they are placed on the market.

Prior to the introduction of ISO 10993-1:2017, various national standards and regulations existed, resulting in discrepancies and inconsistency in testing protocols. The need for a unified approach led to the development of ISO 10993-1, which provides a standardized framework for evaluating the biological safety of medical devices.

ISO 10993-1 covers a wide range of factors related to biocompatibility, including cytotoxicity, genotoxicity, sensitization, irritation, and systemic toxicity. By assessing these factors, manufacturers can identify potential risks associated with their medical devices and take necessary steps to mitigate them.

Key Changes in ISO 10993-1:2017

The updated version of ISO 10993-1, published in 2017, incorporates several important changes aimed at improving the evaluation process and aligning it with current scientific understanding.

One significant change is the emphasis on a risk-based approach. ISO 10993-1:2017 encourages manufacturers to assess the biological risks associated with their specific device and its intended use. This approach allows for a more tailored evaluation, taking into account factors such as contact duration, route of exposure, and patient population.

Another notable change is the inclusion of updated guidelines for chemical characterization. ISO 10993-1:2017 emphasizes the need for comprehensive information regarding the materials used in medical devices, including their chemical composition and potential impurities. This information can help identify any toxic substances that could pose a risk to patients.

Implementing ISO 10993-1:2017

Manufacturers seeking compliance with ISO 10993-1:2017 should follow a systematic approach to biological evaluation. The first step involves conducting a risk assessment, taking into account factors such as device classification, intended use, patient population, and duration of contact.

Next, manufacturers should perform the necessary tests to evaluate the biological safety of their device, following the protocols outlined in ISO 10993-1:2017. These tests may include cytotoxicity testing, sensitization testing, and irritation testing, among others.

It is important for manufacturers to document all steps taken during the evaluation process, as well as the results obtained. This documentation serves as evidence of compliance with ISO 10993-1:2017 requirements and can be reviewed during regulatory inspections.

By implementing ISO 10993-1:2017, manufacturers can ensure the safety and biocompatibility of their medical devices, instilling confidence in both healthcare professionals and patients. Additionally, adherence to this standard helps facilitate global market access by demonstrating compliance with international regulations.

Contact Us

Contact: Nina She

Phone: +86-13751010017

Tel: +86-755-33168386

Add: 1F Junfeng Building, Gongle, Xixiang, Baoan District, Shenzhen, Guangdong, China

close
Scan the qr codeClose
the qr code